Skip to content
Check free

Building regulations

Garden room building regulations: the 15 m² and 30 m² lines, the 1 m boundary rule and sleeping

Building regulations are a separate law from planning. This guide sets out the exemption lines in each nation: size, the 1 m boundary test, sleeping, and what still applies when a garden room is exempt.

By Garden Room CheckUpdated 8 min readChecked against 5 sources

Garden room under construction where building regulations apply to the electricsIllustration

The short answer

In England and Wales a detached, single storey garden room with no sleeping accommodation is exempt from building regulations up to 15 m² of floor area. Between 15 m² and 30 m² it is exempt only if no point is within 1 m of the boundary or it is substantially non-combustible. Over 30 m², or with a bed, approval is needed.

Building regulations and planning are two separate laws, run by different parts of the council with different tests. A garden room can pass one and fail the other, and passing one says nothing about the other. This guide covers building regulations only: when a garden room is exempt, when it is not, and what still applies when it is exempt.

The tests turn on floor area, distance from a boundary, what the room is built from and whether anyone sleeps in it. England and Wales share one rule. Scotland and Northern Ireland have their own.

England and Wales: Schedule 2, Class 6

The exemption is in Schedule 2 of the Building Regulations 2010, Class 6, “Small detached buildings”. legislation.gov.uk marks Schedule 2 as applying in both England and Wales and, at the date we read it (18 November 2026), as up to date. Class 6 reads the same in both nations.

There are three tiers, and the 15 m² and 30 m² lines are floor area, not the outside footprint.

Up to 15 m² inside, no sleeping: exempt

Class 6 exempts a detached building with a floor area that does not exceed 15 m² and contains no sleeping accommodation. There is no boundary test and no material test at this size. The room must be detached, meaning it does not join the house.

15 to 30 m²: exempt only with the 1 m or non-combustible test

Between 15 m² and 30 m², the building must be a single storey, detached, with no sleeping accommodation, and must satisfy one of two tests. Either no point of it is less than 1 m from the boundary of its curtilage, or it is constructed substantially of non-combustible material. A timber garden room that sits closer than 1 m to the fence fails both, and needs approval.

Over 30 m², joined to the house or with sleeping: approval needed

Above 30 m² the exemption does not apply. Nor does it apply to a room joined to the house, because the class covers detached buildings only. And sleeping accommodation ends it at any size, which the next sections cover.

Garden room England and Wales building regulations
Detached, up to 15 m² inside, no sleeping Exempt
Detached, single storey, 15 to 30 m², no sleeping, 1 m clear of the boundary Exempt
Detached, single storey, 15 to 30 m², no sleeping, substantially non-combustible Exempt
Detached, 15 to 30 m², closer than 1 m and combustible Approval needed
Over 30 m², or attached to the house Approval needed
Any size with sleeping accommodation Approval needed

The 1 metre rule

The test is that no point of the building is less than 1 m from the boundary of its curtilage. Two details catch people.

Measured to the roof edge

Class 6 says “no point”. That reads as the furthest-out part of the building, which includes the overhang of the roof and the gutter, not just the wall. A wall 1.1 m from the fence with a 300 mm overhang puts a point of the roof 800 mm from it, which fails the test. Our checker measures to the roof edge for this reason. The wording is the legislation’s; how a building control body reads an edge case is for them, so ask before you rely on a few millimetres.

Boundary of the curtilage

The test is the boundary of the curtilage, not the distance to the neighbour’s house.

Why it is not the planning rule

Planning has its own boundary and height tests for outbuildings. They are a different law with different numbers, and they are set out in the height limits guide. Do not mix the two.

Sleeping accommodation ends the exemption

Every tier of Class 6 says “contains no sleeping accommodation”. A garden room with a bed in it as a guest room, a teenager’s room or a rental falls outside Class 6 at any size, and the building regulations apply. Whether sleeping is lawful as a use is a planning question, which is covered in can you sleep in a garden room. For building regulations the line is simpler: if it is designed or used for sleeping, plan for approval.

Check with your council

A home office is not a bedroom, until it is

A room built as an office is exempt if it meets the size and distance tests. Fitting a bed and a shower later, or advertising it to let, can take it out of the exemption. Tell building control what the room is for.

Exempt is not “no rules”

An exempt garden room is still a building people use, and some requirements reach it even though full approval does not.

Electrics: Part P

Regulation 9(3) of the Building Regulations 2010 applies the requirements of Part P of Schedule 1 to a Class 6 building that receives its electricity from a source shared with, or inside, a dwelling. That covers a garden room supplied from the house. Use a registered electrician, and ask for the certificate.

Water: G1 and G3

Regulation 9(2) applies paragraphs G1 and G3(2) and (3) of Schedule 1 to a Class 6 building that receives a cold or hot water supply from a source shared with, or inside, a building that is not itself exempt. A tap, a sink or a shower fed from the house triggers these requirements.

Drains and a WC

The paragraphs of regulation 9 we have read do not mention drainage. A WC or shower means waste water has to go somewhere, and the drainage connection is the part to check with building control before you dig, because drains are shared and regulated separately. We have not opened a source that says drainage is or is not covered by the exemption, so we do not state it.

Scotland: the building warrant

Scotland does not use Class 6. The Building (Scotland) Regulations 2004 exempt small buildings in Schedule 1 and let others proceed without a warrant under Schedule 3. Both are on legislation.gov.uk, and we read both on 18 November 2026.

Schedule 1, type 17: up to 8 m²

Type 17 is a detached single storey building ancillary to and within the curtilage of a house. The regulations do not apply at all to it, except it must not exceed 8 m², be within 1 m of the house unless it is at least 1 m from any boundary, contain sleeping accommodation, contain a flue, a fixed combustion appliance installation or a sanitary facility.

Schedule 3, type 4: 8 m² to 30 m²

Type 4 covers a detached single storey building over 8 m² and up to 30 m², ancillary to a house and within its curtilage. It needs no building warrant, but must still meet the building standards. The exceptions are a building within 1 m of the house unless at least 1 m from any boundary, a fixed combustion appliance installation or sanitary facility, and a swimming pool deeper than 1.2 m.

What needs a warrant

Over 30 m², more than one storey, joined to the house, or with a stove or a WC or shower, a building warrant is needed from your council before work starts. Type 4 does not list sleeping accommodation as an exception, type 17 does, so check sleeping with your council. The planning side in Scotland is in Scotland garden room permitted development.

Northern Ireland: Schedule 2, Class 7

In Northern Ireland the exempt classes are in Schedule 2 of the Building Regulations (Northern Ireland) 2012, and Class 7 covers small detached buildings. We read it on legislation.gov.uk on 18 November 2026.

Up to 15 m²

A detached single storey building up to 15 m² with no sleeping accommodation, not less than 1 m from a dwelling, is exempt under Class 7(c).

15 to 30 m²

Up to 30 m² the building must be detached, single storey, with no sleeping accommodation, and either constructed substantially of non-combustible material or at no point less than 1 m from the nearest point of a dwelling, the nearest part of a road and the boundary of the land. Two differences from England and Wales stand out: the distance test counts the dwelling and any road as well as the boundary, and the 15 m² tier must be 1 m from a dwelling. Planning in Northern Ireland is in Northern Ireland garden room permitted development.

Internal and external area

Class 6 and its equivalents turn on floor area. Regulation 2 of the 2010 Regulations defines floor area as the area of every floor calculated by reference to the finished internal faces of the walls, so it is the inside figure. The size on a catalogue or a planning drawing is usually the outside footprint, and a garden room with 100 mm walls loses 200 mm in each direction inside. Our checker estimates the inside area with 100 mm walls, which is an estimate: your real wall thickness depends on the build. A room advertised as 3.5 m by 4.5 m outside is about 3.3 m by 4.3 m inside, which is 14.2 m². That is under 15 m², but only just, so measure the real build before relying on it.

The building regulations checker takes your dimensions, whether anyone sleeps in the room and the distance to the boundary, and returns the result for your nation.

Your council’s building control decides whether building regulations apply; the check shows how the design reads against the rule. The free 3D check on Garden Room Check prints the building regulations result beside the planning one, so you see both before you spend on a build.

Sources

Every number in this guide that does not come from our own 3D check was checked against these 5 documents, numbered in the order the text first cites them and read between 11 November 2026 and 19 November 2026. 5 are legislation and government guidance.

  1. 1legislation.gov.ukThe Building Regulations 2010, Schedule 2, Class 6 (small detached buildings), England and Wales
  2. 2legislation.gov.ukThe Building Regulations 2010, regulation 9: exempt buildings and work; Part P and requirements G1 and G3 still apply to a Class 6 building
  3. 3legislation.gov.ukThe Building Regulations 2010, regulation 2: floor area measured to the finished internal faces of the walls
  4. 4legislation.gov.ukThe Building (Scotland) Regulations 2004, Schedule 1 type 17 and Schedule 3 type 4 (small detached buildings)
  5. 5legislation.gov.ukThe Building Regulations (Northern Ireland) 2012, Schedule 2, Class 7 (small detached buildings)

Questions

Anything else? Write to us or browse every guide.

Questions people ask

Not always. In England and Wales a detached, single storey outbuilding with no sleeping accommodation is exempt up to 15 m² of floor area. Between 15 m² and 30 m² it is exempt if no point is within 1 m of the boundary of the curtilage or if it is built substantially of non-combustible material. Over 30 m², or with sleeping accommodation, the regulations apply (Building Regulations 2010, Schedule 2, Class 6). Scotland and Northern Ireland have their own tests, set out below.

For building regulations in England and Wales, a garden building between 15 m² and 30 m² that is not non-combustible must have no point within 1 m of the boundary of its curtilage. Under 15 m² the distance does not matter for this test. Planning permitted development has its own boundary rules and heights, which are covered in the height limits guide.

For a garden room the planning answer depends on the room as a whole, which the free check reads against the rule. The building side is separate. In Scotland a sanitary facility takes a garden building out of both the exemption (type 17) and the no-warrant route (type 4), so a warrant is needed. In England and Wales a WC does not itself remove the Class 6 exemption, but a water supply shared with a house brings in requirements G1 and G3, and drainage is worth confirming with building control before you build.

In England and Wales it is the test in Schedule 2, Class 6 of the Building Regulations 2010: a detached single storey building of 15 m² to 30 m² with no sleeping accommodation is exempt if no point of it is less than 1 m from the boundary of its curtilage, or if it is substantially non-combustible. It is a building regulations rule, separate from the planning boundary tests.